UL FEP High temperature Teflon line150℃200℃

UL1330-UL1331-UL1332-UL1333-UL1901-UL10064-UL10633-UL11331High temperature Teflon line

Key words:

铁氟龙线 高温线 UL1330-UL1331-UL1332-UL1333-UL1901-UL10064-UL10633-UL11331

Describe

UL1330 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 1330 AWG NO. 200℃ 600V VW-1 

c1 AWM I A 200℃ 600V FT1 -LF- ELETECK

 

Product manual:

- Rated temperature:200℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.51
1.32
381
28
7/0.12
0.36
0.51
1.38
239
26
7/0.16
0.48
0.51
1.50
150
24
19/0.12
0.60
0.51
1.62
94.2
22
7/0.25
0.75
0.51
1.77
59.4
22
19/0.15
0.75
0.51
1.77
59.4
20
7/0.31
0.93
0.51
1.95
36.7
20
19/0.19
0.93
0.51
1.95
36.7

 

UL1331 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 1331 AWG NO. 150℃ 600V VW-1 

c1 AWM I A 150℃ 600V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:150℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.51
1.32
381
28
7/0.12
0.36
0.51
1.38
239
26
7/0.16
0.48
0.51
1.50
150
24
19/0.12
0.60
0.51
1.62
94.2
22
7/0.25
0.75
0.51
1.77
59.4
22
19/0.15
0.75
0.51
1.77
59.4
20
7/0.31
0.93
0.51
1.95
36.7
20
19/0.19
0.93
0.51
1.95
36.7

 

UL1332 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-10AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 1332 AWG NO. 200℃ 300V VW-1 

c1 AWM I A 200℃ 300V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:200℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.33
0.96
381
28
7/0.12
0.36
0.33
1.02
239
26
7/0.16
0.48
0.33
1.14
150
24
19/0.12
0.60
0.33
1.26
94.2
22
7/0.25
0.75
0.33
1.41
59.4
22
19/0.15
0.75
0.33
1.41
59.4
20
7/0.31
0.93
0.33
1.59
36.7
20
19/0.19
0.93
0.33
1.59
36.7

 

UL1333 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-10AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 1333 AWG NO. 150℃ 300V VW-1 

c1 AWM I A 150℃ 300V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:150℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.33
0.96
381
28
7/0.12
0.36
0.33
1.02
239
26
7/0.16
0.48
0.33
1.14
150
24
19/0.12
0.60
0.33
1.26
94.2
22
7/0.25
0.75
0.33
1.41
59.4
22
19/0.15
0.75
0.33
1.41
59.4
20
7/0.31
0.93
0.33
1.59
36.7
20
19/0.19
0.93
0.33
1.59
36.7
 

 

UL1901 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 1901 AWG NO. 200℃ 600V VW-1 

c1 AWM I A 200℃ 600V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:200℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.36
1.02
381
28
7/0.12
0.36
0.36
1.08
239
26
7/0.16
0.48
0.36
1.20
150
24
19/0.12
0.60
0.36
1.32
94.2
22
7/0.25
0.75
0.36
1.47
59.4
22
19/0.15
0.75
0.36
1.47
59.4
20
7/0.31
0.93
0.36
1.65
36.7
20
19/0.19
0.93
0.36
1.65
36.7

 

UL10064 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 40AWG minimum, FEP insulation

 

Printing

E254881 1 AWM STYLE 10064 AWG NO. 105℃ 30V VW-1 

c1 AWM I A 105℃ 30V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:105℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
36
7/0.05
0.15
0.06
0.27
1552
34
7/0.06
0.18
0.06
0.30
978
34
7/0.06
0.18
0.07
0.32
978
32
7/0.08
0.24
0.05
0.34
601
32
7/0.08
0.24
0.07
0.38
601
30
7/0.10
0.30
0.10
0.50
381
28
7/0.12
0.36
0.10
0.56
239
26
7/0.16
0.48
0.10
0.70
150

 

UL10633 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 10633 AWG NO. 200℃ 600V VW-1 

c1 AWM I A 200℃ 600V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:200℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210 

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.33
0.96
381
28
7/0.12
0.36
0.33
1.02
239
26
7/0.16
0.48
0.33
1.14
150
24
19/0.12
0.60
0.33
1.26
94.2
22
7/0.25
0.75
0.33
1.41
59.4
22
19/0.15
0.75
0.33
1.41
59.4
20
7/0.31
0.93
0.33
1.59
36.7
20
19/0.19
0.93
0.33
1.59
36.7
 

 

UL11331 FEP Insulated Wire

Tinned or bare, stranded or solid copper conductor, 50-10AWG, FEP insulation

 

Printing

E254881 1 AWM STYLE 11331 AWG NO. 200℃ 600V VW-1 

c1 AWM I A 200℃ 600V FT1 -LF- ELETECK

 

Product manual

- Rated temperature:200℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
20℃
Maximum Resistance
at(Ω/km)
AWG
No./mm
Diamater(mm)
Thicknes(mm)
Diamater(mm)
30
7/0.10
0.30
0.26
0.82
381
28
7/0.12
0.36
0.26
0.88
239
26
7/0.16
0.48
0.26
1.00
150
24
19/0.12
0.60
0.26
1.12
94.2
22
7/0.25
0.75
0.26
1.27
59.4
22
19/0.15
0.75
0.26
1.27
59.4
20
7/0.31
0.93
0.26
1.45
36.7
20
19/0.19
0.93
0.26
1.45
36.7

 

Related Products

Online consultation