Welcome to Eleteck Wire & Cable official website!

Service:/+86(0)13923630026(Sally) / +86(0)13692867958(Linda) 

Comprehensive coverage of all areas

UL AWM Wire type 185

Let you choose worry-free

Your location:
Homepage
/
/
PVC Multi-conductor Shielded Cable

Service:

+86(0)13692867958(Linda)

+86(0)13923630614(Aries)

PVC Multi-conductor Shielded Cable

 
 
Product description

 

UL2095 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2095  NO. 80℃ 300V VW-1 

c1 AWM I A 80℃ 300V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
Thickness(mm)
Diamater(mm)
2
28
7/0.127
0.26
0.90
0.50
2.80
239
3
28
7/0.127
0.30
1.00
0.50
3.10
239
4
24
11/0.16
0.26
1.12
0.60
4.00
94.2
5
24
11/0.16
0.26
1.12
0.70
4.50
94.2

 

UL2464 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2464  NO. 80℃ 300V VW-1 

c1 AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
3
28
7/0.127
0.26
0.90
16/4/0.10
4.00
239
4
28
7/0.127
0.26
0.90
16/4/0.12
4.80
239
5
28
7/0.127
0.26
0.90
16/4/0.12
5.00
239
6
28
7/0.127
0.26
0.90
16/5/0.12
5.00
239
8
28
7/0.127
0.26
0.90
16/7/0.10
5.00
239
12
28
7/0.16
0.26
0.90
16/7/0.12
6.00
239
18
28
7/0.127
0.26
0.90
16/7/0.12
7.40
239
9
26
7/0.16
0.26
1.00
16/6/0.12
6.30
150
11
26
7/0.16
0.26
1.00
16/8/0.12
6.60
150
15
24
11/0.16
0.26
1.12
24/7/0.12
8.00
94.2
20
24
7/0.20
0.26
1.12
24/8/0.12
8.50
94.2

 

UL2517 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

印字

E254881 1 AWM STYLE 2517  NO. 105℃ 300V VW-1 

c1 AWM I/II A/B 105℃ 300V FT1 -LF- ELETECK

 

product manual

- Rated temperature:105℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
3
28
7/0.127
0.41
1.20
16/4/0.10
4.20
239
4
28
7/0.127
0.41
1.20
16/4/0.12
4.70
239
5
28
7/0.127
0.41
1.20
16/4/0.12
5.00
239
6
28
7/0.127
0.41
1.20
16/5/0.12
5.30
239
8
28
7/0.127
0.41
1.20
16/7/0.10
5.80
239
12
28
7/0.16
0.41
1.20
16/7/0.12
7.10
239
18
28
7/0.127
0.41
1.20
16/7/0.12
7.80
239
9
26
7/0.16
0.41
1.30
16/6/0.12
6.40
150
11
26
7/0.16
0.41
1.30
16/8/0.12
6.90
150

 

UL2547 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, 30-16AWG, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2547  NO. 80℃ 300V VW-1 

c1 AWM I A 80℃ 300V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
2
30
7/0.10
0.26
0.82
44/0.10
2.64
381
3
30
7/0.10
0.26
0.82
49/0.10
2.77
381
2
28
7/0.127
0.26
0.90
46/0.10
2.80
239
3
28
7/0.127
0.26
0.90
53/0.10
2.94
239
2
26
7/0.16
0.26
1.00
54/0.10
3.00
150
3
26
7/0.16
0.26
1.00
62/0.10
2.90
150
2
24
11/0.16
0.26
1.13
62/0.10
3.26
94.2
3
24
11/0.16
0.26
1.13
69/0.10
3.43
94.2
2
22
11/0.16
0.26
1.28
60/0.12
3.60
59.4
3
22
11/0.16
0.26
1.28
72/0.12
3.76
59.4

 

UL2586 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2586  NO. 105℃ 600V VW-1 

c1 AWM I/II A/B 105℃ 600V FT1 -LF- ELETECK

 

product manual

- Rated temperature:105℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
2
22
7/0.254
0.32
1.40
-
4.50
59.4
2
20
26/0.16
0.76
2.50
-
6.70
36.7
2
18
41/0.16
0.76
2.80
-
7.20
23.2
2
16
26/0.254
0.76
3.00
-
7.60
14.6
3
16
26/0.254
0.76
3.00
-
8.20
14.6
2
14
41/0.254
0.51
3.00
24/7/0.12
8.50
8.96
3
14
41/0.254
0.51
3.00
24/8/0.12
9.20
8.96

 

UL2725 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2725  NO. 80℃ 30V VW-1 

c1 AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
4
30x1P
7/0.10
0.20
0.70
16/4/0.10
3.50
381
28x2C
7/0.127
0.20
0.80
239
4
28x1P
7/0.127
0.20
0.80
16/4/0.10
3.50
239
28x2C
7/0.127
0.20
0.80
239
4
28x1P
7/0.127
0.20
0.80
16/4/0.12
4.00
239
26x2C
7/0.16
0.20
1.00
150
4
 
28x1P
7/0.127
0.20
0.80
16/4/0.12
4.50
239
24x2C
11/0.16
0.20
1.10
94.2
6
28x1P
7/0.127
0.20
0.80
16/5/0.10
4.50
239
28x4C
7/0.127
0.20
0.80
239

 

UL2791 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC,PP or PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2791  NO. 80℃ 30V VW-1 

c1 AWM I A 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
2
 
30
7/0.10
0.26
0.82
44/0.10
2.64
381
3
30
7/0.10
0.26
0.82
49/0.10
2.77
381
2
28
7/0.127
0.26
0.90
46/0.10
2.80
239
3
28
7/0.127
0.26
0.90
53/0.10
2.94
239
2
26
7/0.16
0.26
1.00
54/0.10
3.00
150
3
26
7/0.16
0.26
1.00
54/0.10
2.90
150
2
24
11/0.16
0.26
1.13
62/0.10
3.26
94.2
3
24
11/0.16
0.26
1.13
69/0.10
3.43
94.2
2
22
17/0.16
0.26
1.28
60/0.12
3.60
59.4
3
22
17/0.16
0.26
1.28
72/0.12
3.76
59.4

 

UL2835 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2835  NO. 60℃ 30V VW-1 

c1 AWM I/II A/B 60℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:60℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
4
 
28
7/0.127
0.22
0.82
16/4/0.10
3.50
239
5
28
7/0.127
0.22
0.82
16/4/0.12
3.60
239
6
28
7/0.127
0.22
0.82
16/4/0.12
3.80
239
7
28
7/0.127
0.22
0.82
16/4/0.12
4.00
239
8
28
7/0.127
0.22
0.82
-
4.20
239
9
28
7/0.127
0.22
0.82
-
4.30
239
10
28
7/0.127
0.22
0.82
-
4.50
239

 

UL2844 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2844  NO. 80℃ 30V VW-1 

c1 AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
10
 
28
7/0.127
0.15
0.68
16/4/0.10
4.50
239
16
30
7/0.1
0.18
0.66
16/4/0.10
5.10
381

 

UL2851 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2851  NO. 80℃ 30V VW-1 

c1 AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
2
30
7/0.10
0.23
0.75
41/0.10
2.42
381
3
30
7/0.10
0.23
0.75
46/0.10
2.55
381
4
30
7/0.10
0.23
0.75
56/0.10
2.80
381
5
30
7/0.10
0.23
0.75
68/0.10
2.93
381
6
30
7/0.10
0.23
0.75
59/0.10
3.20
381
7
30
7/0.10
0.23
0.75
59/0.10
3.20
381
2
28
7/0.127
0.26
0.90
46/0.10
2.80
239
3
28
7/0.127
0.26
0.90
53/0.10
3.10
239
4
28
7/0.127
0.26
0.90
56/0.10
3.10
239
5
28
7/0.127
0.26
0.90
62/0.12
3.37
239
6
28
7/0.127
0.26
0.90
71/0.12
3.64
239
7
28
7/0.127
0.26
0.90
71/0.12
4.00
239
2
26
7/0.16
0.26
1.00
54/0.10
2.94
150
3
26
7/0.16
0.26
1.00
62/0.10
3.10
150
4
26
7/0.16
0.26
1.00
63/0.12
3.35
150
5
26
7/0.16
0.26
1.00
71/0.12
3.64
150
6
26
7/0.16
0.26
1.00
79/0.12
3.94
150

 

UL2854 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 2854 AWG NO. 80℃ 30V VW-1 

c1 AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
2
30
7/0.10
0.23
0.75
41/0.10
2.42
381
3
30
7/0.10
0.23
0.75
46/0.10
2.55
381
4
30
7/0.10
0.23
0.75
56/0.10
2.80
381
5
30
7/0.10
0.23
0.75
68/0.10
2.93
381
6
30
7/0.10
0.23
0.75
59/0.10
3.20
381
7
30
7/0.10
0.23
0.75
59/0.10
3.20
381
2
28
7/0.127
0.26
0.90
46/0.10
2.80
239
3
28
7/0.127
0.26
0.90
53/0.10
3.10
239
4
28
7/0.127
0.26
0.90
56/0.10
3.10
239
5
28
7/0.127
0.26
0.90
62/0.12
3.37
239
6
28
7/0.127
0.26
0.90
71/0.12
3.64
239
7
28
7/0.127
0.26
0.90
71/0.12
4.00
239
2
26
7/0.16
0.26
1.00
54/0.10
2.94
150
3
26
7/0.16
0.26
1.00
62/0.10
3.10
150
4
26
7/0.16
0.26
1.00
63/0.12
3.35
150
5
26
7/0.16
0.26
1.00
71/0.12
3.64
150
6
26
7/0.16
0.26
1.00
79/0.12
3.94
150

 

UL20167 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 20167 AWG NO. 80℃ 300V VW-1 

c1 AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK

 

product manual

- Rated temperature:80℃,90℃,105℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
3
28
7/0.127
0.23
0.90
-
2.90
239
4
28
7/0.127
0.23
0.90
-
3.00
239
5
28
7/0.127
0.23
0.90
-
3.20
239
2
26
7/0.16
0.23
1.00
-
3.00
150
3
26
7/0.16
0.23
1.00
-
3.20
150
4
26
7/0.16
0.26
1.00
-
3.50
150
5
26
7/0.16
0.26
1.00
-
3.70
150
2
24
11/0.16
0.26
1.15
-
3.40
94.2
2
22
17/0.16
0.26
1.25
-
3.50
59.4
2
20
26/0.16
0.26
1.46
-
4.00
36.7

 

UL20251 Telephon Cable

Stranded Tinned or bare copper conductor, PP insulation, PVC jacket

 

Printing

E254881 1 AWM STYLE 20251  NO. 60℃ 150V VW-1 -LF- ELETECK

 

product manual

- Rated temperature:60℃

- Rated voltage:150V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
Diamater(mm)
2
28
7/0.12
0.29
0.94
2.50*5.00
239
4
28
7/0.12
0.29
0.94
2.50*5.00
239
6
28
7/0.12
0.29
0.94
2.50*7.00
150
2
26
7/0.16
0.23
0.94
2.50*5.00
150
4
26
7/0.16
0.23
0.94
2.50*5.00
150
6
26
7/0.16
0.23
0.94
2.50*7.00
150

 

UL20276 Multi-conductor Shielded Cable

Stranded Tinned or bare copper conductor, PVC insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), PVC jacket

 

Printing

E254881 1 AWM STYLE 20276  NO. 80℃ 30V VW-1 

c1 AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK

 

product manual

- Rated temperature:60℃

- Rated voltage:30V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

 

Conductor
Insulation
Shield
Jacket
20℃
Maximum Resistance(Ω/km)
Cores
AWG
No./mm
Thickness(mm)
Diamater(mm)
No./mm
Diamater(mm)
3P+1C
 
26
7/0.16
0.26
1.00
85%
6.40
150
26
7/0.16
0.26
1.00
85%
6.40
150
3P+9C
 
28
7/0.127
0.12
0.63
85%
4.70
239
28
7/0.127
0.12
0.63
85%
4.70
239
6P
26
7/0.127
0.12
0.63
85%
4.70
239
7P
26
7/0.127
0.12
0.63
85%
5.30
239
8P
26
7/0.127
0.12
0.63
85%
5.00
239