Comprehensive coverage of all areas
UL AWM Wire type 185
Let you choose worry-free
Multi-conductor Shielded Cable
UL20233 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 300V VW-1
c AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
3
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
3.50
|
239
|
4
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
3.60
|
239
|
7
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
4.20
|
239
|
3
|
26
|
7/0.16
|
0.23
|
1.00
|
-
|
4.30
|
150
|
4
|
26
|
7/0.16
|
0.23
|
1.00
|
-
|
4.50
|
150
|
5
|
24
|
11/0.16
|
0.23
|
1.12
|
-
|
5.20
|
94.2
|
6
|
24
|
11/0.16
|
0.23
|
1.12
|
-
|
5.50
|
94.2
|
7
|
22
|
17/0.16
|
0.23
|
1.28
|
-
|
6.10
|
59.4
|
3
|
20
|
26/0.16
|
0.23
|
1.46
|
-
|
5.30
|
36.7
|
4
|
18
|
41/0.16
|
0.31
|
1.80
|
-
|
6.00
|
23.2
|
2
|
18
|
41/0.16
|
0.31
|
1.80
|
-
|
5.50
|
23.2
|
6
|
18*2C
|
41/0.16
|
0.31
|
1.80
|
-
|
5.40
|
23.2
|
26*4C
|
7/0.16
|
0.20
|
0.90
|
-
|
5.40
|
150
|
UL20236 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 300V VW-1
c AWM I/II A/B 80℃ 30V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:30V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
2
|
30
|
7/0.10
|
0.23
|
0.80
|
>=65%
|
3.70
|
381
|
2
|
28
|
7/0.127
|
0.23
|
0.90
|
>=65%
|
4.00
|
239
|
2
|
26
|
7/0.16
|
0.23
|
1.00
|
>=65%
|
4.20
|
150
|
2
|
24
|
11/0.16
|
0.23
|
1.10
|
>=65%
|
4.40
|
94.2
|
2
|
22
|
17/0.16
|
0.23
|
1.30
|
>=65%
|
4.70
|
59.4
|
2
|
20
|
26/0.16
|
0.23
|
1.50
|
>=65%
|
5.20
|
36.7
|
2
|
18
|
41/0.16
|
0.23
|
1.80
|
>=65%
|
5.80
|
23.2
|
2
|
16
|
26/0.254
|
0.23
|
2.00
|
>=65%
|
6.20
|
14.6
|
3
|
30
|
7/0.10
|
0.23
|
0.80
|
>=65%
|
3.80
|
381
|
3
|
28
|
7/0.127
|
0.23
|
0.90
|
>=65%
|
4.00
|
239
|
3
|
26
|
7/0.16
|
0.23
|
1.00
|
>=65%
|
4.00
|
150
|
3
|
24
|
11/0.16
|
0.23
|
1.10
|
>=65%
|
4.50
|
94.2
|
3
|
22
|
17/0.16
|
0.23
|
1.30
|
>=65%
|
4.90
|
59.4
|
3
|
20
|
26/0.16
|
0.23
|
1.50
|
>=65%
|
5.40
|
36.7
|
3
|
18
|
41/0.16
|
0.23
|
1.80
|
>=65%
|
6.00
|
23.2
|
4
|
30
|
7/0.10
|
0.23
|
0.80
|
>=65%
|
4.00
|
381
|
4
|
28
|
7/0.127
|
0.23
|
0.90
|
>=65%
|
4.30
|
239
|
4
|
26
|
7/0.16
|
0.23
|
1.00
|
>=65%
|
4.50
|
150
|
4
|
24
|
11/0.16
|
0.23
|
1.10
|
>=65%
|
4.80
|
94.2
|
4
|
22
|
17/0.16
|
0.23
|
1.30
|
>=65%
|
5.30
|
59.4
|
4
|
20
|
26/0.16
|
0.23
|
1.50
|
>=65%
|
5.60
|
36.7
|
5
|
30
|
7/0.10
|
0.23
|
0.80
|
>=65%
|
4.30
|
381
|
5
|
28
|
7/0.127
|
0.23
|
0.90
|
>=65%
|
4.50
|
239
|
5
|
26
|
7/0.16
|
0.23
|
1.00
|
>=65%
|
4.80
|
150
|
5
|
24
|
11/0.16
|
0.23
|
1.10
|
>=65%
|
5.00
|
94.2
|
5
|
22
|
17/0.16
|
0.23
|
1.30
|
>=65%
|
5.60
|
59.4
|
6
|
30
|
7/0.10
|
0.23
|
0.80
|
>=65%
|
4.50
|
381
|
6
|
28
|
7/0.127
|
0.23
|
0.90
|
>=65%
|
4.80
|
239
|
6
|
26
|
7/0.16
|
0.23
|
1.00
|
>=65%
|
5.20
|
150
|
6
|
24
|
11/0.16
|
0.23
|
1.10
|
>=65%
|
5.40
|
94.2
|
UL20280 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copStranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 300V VW-1
c AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1及CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
5
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
5.00
|
239
|
6
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
5.00
|
239
|
9
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
5.00
|
239
|
14
|
28
|
7/0.127
|
0.23
|
0.85
|
-
|
5.50
|
239
|
4
|
26
|
7/0.16
|
0.23
|
1.00
|
-
|
4.50
|
150
|
5
|
24
|
11/0.16
|
0.23
|
1.12
|
-
|
5.20
|
94.2
|
6
|
24
|
11/0.16
|
0.23
|
1.12
|
-
|
5.50
|
94.2
|
7
|
22
|
17/0.16
|
0.23
|
1.28
|
-
|
6.10
|
59.4
|
3
|
20
|
26/0.16
|
0.23
|
1.46
|
-
|
5.30
|
36.7
|
4
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
6.00
|
23.2
|
2
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
5.50
|
23.2
|
3
|
18*2C
|
41/0.16
|
0.30
|
1.80
|
-
|
6.00
|
23.2
|
16*1C
|
26/0.254
|
0.30
|
2.10
|
-
|
6.00
|
14.6
|
UL20549 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 300V VW-1
c AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
4
|
26
|
7/0.16
|
0.23
|
1.00
|
-
|
4.50
|
150
|
5
|
24
|
41/0.16
|
0.23
|
1.10
|
-
|
5.80
|
94.2
|
4
|
22
|
20/0.15
|
0.23
|
1.25
|
16/8/0.10
|
4.80
|
59.4
|
5
|
22
|
20/0.15
|
0.23
|
1.25
|
16/8/0.10
|
5.30
|
59.4
|
3
|
20
|
26/0.16
|
0.23
|
1.46
|
-
|
5.30
|
36.7
|
6
|
20
|
65/0.10
|
0.23
|
1.50
|
-
|
7.50
|
36.7
|
4
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
6.00
|
23.2
|
2
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
5.50
|
23.2
|
6
|
18*2C
|
41/0.16
|
0.31
|
1.80
|
-
|
5.40
|
23.2
|
26*4C
|
7/0.16
|
0.20
|
0.90
|
-
|
5.40
|
150
|
UL20940 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 600V VW-1
c AWM I/II A/B 80℃ 600V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
2
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
4.95
|
381
|
2
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.25
|
239
|
2
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
5.65
|
150
|
2
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
5.95
|
94.2
|
2
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.25
|
59.4
|
2
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
6.65
|
36.7
|
2
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
7.25
|
23.2
|
3
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.25
|
381
|
3
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.55
|
239
|
3
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
5.95
|
150
|
3
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.25
|
94.2
|
3
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.55
|
59.4
|
3
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
6.85
|
36.7
|
3
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
7.45
|
23.2
|
4
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.45
|
381
|
4
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.85
|
239
|
4
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.15
|
150
|
4
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.45
|
94.2
|
4
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.85
|
59.4
|
4
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
7.35
|
36.7
|
4
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
8.05
|
23.2
|
5
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.95
|
381
|
5
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
6.25
|
239
|
5
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.65
|
150
|
5
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.95
|
94.2
|
5
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
7.35
|
59.4
|
5
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
7.95
|
36.7
|
5
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
8.75
|
23.2
|
6
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
6.15
|
381
|
6
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
6.65
|
239
|
6
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.95
|
150
|
6
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
7.25
|
94.2
|
6
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
7.75
|
59.4
|
6
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
8.45
|
36.7
|
6
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
9.35
|
23.2
|
UL21198 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 300V VW-1
c AWM I/II A/B 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
4
|
26
|
7/0.16
|
0.23
|
1.00
|
-
|
4.50
|
150
|
5
|
24
|
41/0.16
|
0.23
|
1.10
|
-
|
5.80
|
94.2
|
4
|
22
|
20/0.15
|
0.23
|
1.25
|
16/8/0.10
|
4.80
|
59.4
|
5
|
22
|
20/0.15
|
0.23
|
1.25
|
16/8/0.10
|
5.30
|
59.4
|
3
|
20
|
26/0.16
|
0.23
|
1.46
|
-
|
5.30
|
36.7
|
3P
|
20
|
16/0.10
|
0.30
|
1.30
|
24/7/12
|
7.60
|
36.7
|
4
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
6.00
|
23.2
|
2
|
18
|
41/0.16
|
0.30
|
1.80
|
-
|
5.50
|
23.2
|
6
|
18*2C
|
41/0.16
|
0.31
|
1.80
|
-
|
5.40
|
23.2
|
26*4C
|
7/0.16
|
0.20
|
0.90
|
-
|
5.40
|
150
|
UL21223 Multi-conductor Shielded Cable
Stranded Tinned or bare copper conductor, PP, PVC, SR-PVC, HDPE, FR-PE insulation, Aluminum mylar shield(Optional), Tinned or bare copper stranded drain wire(Optional), Tinned or bare copper wire braid shield(Optional), TPU jacket
Printing:E254881 AWM STYLE 20233 AWG NO. 80℃ 600V VW-1
c AWM I/II A/B 80℃ 600V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1 and CSA FT1 Vertical burning test
Conductor
|
Insulation
|
Shield
|
Jacket
|
Maximum Resistance
at 20℃(Ω/km) |
|||
AWG
|
AWG
|
No./mm
|
Thickness(mm)
|
Diamater(mm)
|
No./mm
|
Diamater(mm)
|
|
2
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
4.95
|
381
|
2
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.25
|
239
|
2
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
5.65
|
150
|
2
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
5.95
|
94.2
|
2
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.25
|
59.4
|
2
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
6.65
|
36.7
|
2
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
7.25
|
23.2
|
3
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.25
|
381
|
3
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.55
|
239
|
3
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
5.95
|
150
|
3
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.25
|
94.2
|
3
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.55
|
59.4
|
3
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
6.85
|
36.7
|
3
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
7.45
|
23.2
|
4
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.45
|
381
|
4
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
5.85
|
239
|
4
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.15
|
150
|
4
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.45
|
94.2
|
4
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
6.85
|
59.4
|
4
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
7.35
|
36.7
|
4
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
8.05
|
23.2
|
5
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
5.95
|
381
|
5
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
6.25
|
239
|
5
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.65
|
150
|
5
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
6.95
|
94.2
|
5
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
7.35
|
59.4
|
5
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
7.95
|
36.7
|
5
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
8.75
|
23.2
|
6
|
30
|
7/0.10
|
0.41
|
1.10
|
-
|
6.15
|
381
|
6
|
28
|
7/0.127
|
0.41
|
1.20
|
-
|
6.65
|
239
|
6
|
26
|
7/0.16
|
0.41
|
1.30
|
-
|
6.95
|
150
|
6
|
24
|
11/0.16
|
0.41
|
1.40
|
-
|
7.25
|
94.2
|
6
|
22
|
17/0.16
|
0.41
|
1.60
|
-
|
7.75
|
59.4
|
6
|
20
|
26/0.16
|
0.41
|
1.80
|
-
|
8.45
|
36.7
|
6
|
18
|
41/0.16
|
0.41
|
2.10
|
-
|
9.35
|
23.2
|