Comprehensive coverage of all areas
UL AWM Wire type 185
Let you choose worry-free
Reinforced Hook-up Wire
UL1617 Reinforced Hook-up Wire
Tinned or bare, stranded or solid copper conductor, PVC insulation
Printing: E254881 AWM STYLE 1617 AWG NO. 105℃ 600V VW-1
c AWM I A 105℃ 600V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.80
|
0.35
|
2.60
|
381
|
28
|
7/0.127
|
0.38
|
0.80
|
0.35
|
2.68
|
239
|
26
|
7/0.16
|
0.48
|
0.80
|
0.35
|
2.78
|
150
|
24
|
11/0.16
|
0.61
|
0.80
|
0.35
|
2.91
|
94.2
|
22
|
17/0.16
|
0.76
|
0.80
|
0.32
|
3.06
|
59.4
|
20
|
26/0.16
|
0.94
|
0.80
|
0.40
|
3.24
|
36.7
|
18
|
41/0.16
|
1.18
|
0.80
|
0.26
|
3.48
|
23.2
|
16
|
26/0.254
|
1.49
|
0.80
|
0.35
|
3.79
|
14.6
|
UL1618 Reinforced Hook-up Wire
Tinned or bare, stranded or solid copper conductor, PVC insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.41
|
0.40
|
1.29
|
381
|
28
|
7/0.127
|
0.38
|
0.41
|
0.40
|
2.00
|
239
|
26
|
7/0.16
|
0.48
|
0.49
|
0.50
|
2.46
|
150
|
24
|
11/0.16
|
0.61
|
0.46
|
0.50
|
2.53
|
94.2
|
22
|
17/0.16
|
0.76
|
0.48
|
0.48
|
2.68
|
59.4
|
20
|
26/0.16
|
0.94
|
0.41
|
0.42
|
2.60
|
36.7
|
18
|
41/0.16
|
1.18
|
0.41
|
0.38
|
2.76
|
23.2
|
16
|
26/0.254
|
1.49
|
0.41
|
0.40
|
3.12
|
14.6
|
UL1672 Reinforced Hook-up Wire
Tinned or bare, stranded or solid copper conductor, PVC insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.41
|
0.40
|
1.29
|
381
|
28
|
7/0.127
|
0.38
|
0.41
|
0.40
|
2.00
|
239
|
26
|
7/0.16
|
0.48
|
0.49
|
0.50
|
2.46
|
150
|
24
|
11/0.16
|
0.61
|
0.46
|
0.50
|
2.53
|
94.2
|
22
|
17/0.16
|
0.76
|
0.48
|
0.48
|
2.68
|
59.4
|
20
|
26/0.16
|
0.94
|
0.41
|
0.42
|
2.60
|
36.7
|
18
|
41/0.16
|
1.18
|
0.41
|
0.38
|
2.76
|
23.2
|
16
|
26/0.254
|
1.49
|
0.41
|
0.40
|
3.12
|
14.6
|
UL10800 Reinforced Halogen Free Hook-up Wire
Tinned or bare, stranded or solid copper conductor, FRPE insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.30
|
0.42
|
1.74
|
381
|
28
|
7/0.127
|
0.38
|
0.30
|
0.42
|
1.82
|
239
|
26
|
7/0.16
|
0.48
|
0.30
|
0.42
|
1.92
|
150
|
24
|
11/0.16
|
0.61
|
0.30
|
0.42
|
2.05
|
94.2
|
22
|
17/0.16
|
0.76
|
0.30
|
0.42
|
2.20
|
59.4
|
20
|
26/0.16
|
0.94
|
0.30
|
0.42
|
2.38
|
36.7
|
18
|
41/0.16
|
1.18
|
0.30
|
0.42
|
2.62
|
23.2
|
16
|
26/0.254
|
1.49
|
0.30
|
0.42
|
2.93
|
14.6
|
UL10938 Reinforced Halogen Free Hook-up Wire
Tinned or bare, stranded or solid copper conductor, XLPE insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 105℃ 600V VW-1
c AWM I A 105℃ 600V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.80
|
0.35
|
2.60
|
381
|
28
|
7/0.127
|
0.38
|
0.80
|
0.35
|
2.68
|
239
|
26
|
7/0.16
|
0.48
|
0.80
|
0.35
|
2.78
|
150
|
24
|
11/0.16
|
0.61
|
0.80
|
0.35
|
2.91
|
94.2
|
22
|
17/0.16
|
0.76
|
0.80
|
0.35
|
3.06
|
59.4
|
20
|
26/0.16
|
0.94
|
0.80
|
0.35
|
3.24
|
36.7
|
18
|
41/0.16
|
1.18
|
0.80
|
0.35
|
3.48
|
23.2
|
16
|
26/0.254
|
1.49
|
0.80
|
0.35
|
3.79
|
14.6
|
UL11045 Reinforced Halogen Free Hook-up Wire
Tinned or bare, stranded or solid copper conductor, PE insulation, mPPE jacket
Printing:E254881 AWM STYLE 1618 AWG NO. 105℃ 300V VW-1
c AWM I A 105℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.26
|
0.30
|
1.40
|
381
|
28
|
7/0.127
|
0.38
|
0.26
|
0.30
|
1.50
|
239
|
26
|
7/0.16
|
0.48
|
0.26
|
0.30
|
1.60
|
150
|
24
|
11/0.16
|
0.61
|
0.26
|
0.30
|
1.70
|
94.2
|
22
|
17/0.16
|
0.76
|
0.26
|
0.30
|
1.90
|
59.4
|
20
|
26/0.16
|
0.94
|
0.26
|
0.30
|
2.15
|
36.7
|
18
|
41/0.16
|
1.18
|
0.26
|
0.30
|
2.40
|
23.2
|
16
|
26/0.254
|
1.49
|
0.26
|
0.30
|
2.75
|
14.6
|
UL11047 Reinforced Halogen Free Hook-up Wire
Tinned or bare, stranded or solid copper conductor, PE insulation, mPPE jacket
Printing:E254881 AWM STYLE 1618 AWG NO. 105℃ 600V VW-1
c AWM I A 105℃ 600V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.26
|
0.30
|
1.40
|
381
|
28
|
7/0.127
|
0.38
|
0.26
|
0.30
|
1.50
|
239
|
26
|
7/0.16
|
0.48
|
0.26
|
0.30
|
1.60
|
150
|
24
|
11/0.16
|
0.61
|
0.26
|
0.30
|
1.70
|
94.2
|
22
|
17/0.16
|
0.76
|
0.26
|
0.30
|
1.90
|
59.4
|
20
|
26/0.16
|
0.94
|
0.26
|
0.30
|
2.15
|
36.7
|
18
|
41/0.16
|
1.18
|
0.26
|
0.30
|
2.40
|
23.2
|
16
|
26/0.254
|
1.49
|
0.26
|
0.30
|
2.75
|
14.6
|
UL3363 Halogen Free Crosslinked Wire
Tinned or bare, stranded or solid copper conductor, 32-10AWG, XLPE insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 125℃ 300V VW-1
c AWM I A 125℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:125℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.38
|
0.15
|
1.36
|
381
|
28
|
7/0.127
|
0.38
|
0.38
|
0.15
|
1.44
|
239
|
26
|
7/0.16
|
0.48
|
0.38
|
0.15
|
1.54
|
150
|
24
|
11/0.16
|
0.61
|
0.38
|
0.15
|
1.67
|
94.2
|
22
|
17/0.16
|
0.76
|
0.38
|
0.15
|
1.82
|
59.4
|
20
|
26/0.16
|
0.94
|
0.38
|
0.15
|
2.00
|
36.7
|
18
|
41/0.16
|
1.18
|
0.38
|
0.15
|
2.24
|
23.2
|
16
|
26/0.254
|
1.49
|
0.38
|
0.15
|
2.55
|
14.6
|
UL3688 Halogen Free Crosslinked Wire
Tinned or bare, stranded or solid copper conductor, 30-10AWG, XLPE insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 105℃ 3000V VW-1
c AWM I A 105℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:3000V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.38
|
0.15
|
1.36
|
381
|
28
|
7/0.127
|
0.38
|
0.38
|
0.15
|
1.44
|
239
|
26
|
7/0.16
|
0.48
|
0.38
|
0.15
|
1.54
|
150
|
24
|
11/0.16
|
0.61
|
0.38
|
0.15
|
1.67
|
94.2
|
22
|
17/0.16
|
0.76
|
0.38
|
0.15
|
1.82
|
59.4
|
20
|
26/0.16
|
0.94
|
0.38
|
0.15
|
2.00
|
36.7
|
18
|
41/0.16
|
1.18
|
0.38
|
0.15
|
2.24
|
23.2
|
16
|
26/0.254
|
1.49
|
0.38
|
0.15
|
2.55
|
14.6
|
UL3737 Halogen Free Crosslinked Wire
Tinned or bare, stranded or solid copper conductor, 26-9AWG, XLPE insulation
Printing:E254881 AWM STYLE 1618 AWG NO. 105℃ 300V VW-1
c AWM I A 105℃ 300V FT1 -LF- ELETECK
product manual:
- Rated temperature:105℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
by ULVW-1and CSA FT1 CSA FT1Vertical burning test
Conductor
|
Insulation
|
Maximum Resistance
at 20℃(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Primary Layer
Thickness(mm) |
Secondary
Layer Thickness(mm) |
Diamater(mm)
|
|
26
|
7/0.16
|
0.48
|
0.51
|
0.23
|
2.00
|
150
|
24
|
11/0.16
|
0.61
|
0.51
|
0.23
|
2.10
|
94.2
|
22
|
17/0.16
|
0.76
|
0.51
|
0.23
|
2.30
|
59.4
|
20
|
26/0.16
|
0.94
|
0.51
|
0.23
|
2.50
|
36.7
|
18
|
41/0.16
|
1.18
|
0.51
|
0.23
|
2.70
|
23.2
|
16
|
26/0.254
|
1.49
|
0.51
|
0.23
|
3.00
|
14.6
|