Welcome to Eleteck Wire & Cable official website!

Service:400-9302213/18026652017(Mr.Yang)/ 13302658017(Mr.Feng) / 15816429517(Mr.Zhang)

Comprehensive coverage of all areas

UL AWM Wire type 185

Let you choose worry-free

Your location:
Homepage
/
/
Reinforced Hook-up Wire

Service:

400-9302213

18026652017(Mr.Yang)

13302658017(Mr.Feng)

15816429517(Mr.Zhang)

Reinforced Hook-up Wire

 
 
Product description

UL1617 Reinforced Hook-up Wire

 

Tinned or bare, stranded or solid copper conductor, PVC insulation

1

PrintingE254881 1 AWM STYLE 1617 AWG NO. 105℃ 600V VW-1 

c1 AWM I A 105℃ 600V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.80
0.35
2.60
381
28
7/0.127
0.38
0.80
0.35
2.68
239
26
7/0.16
0.48
0.80
0.35
2.78
150
24
11/0.16
0.61
0.80
0.35
2.91
94.2
22
17/0.16
0.76
0.80
0.32
3.06
59.4
20
26/0.16
0.94
0.80
0.40
3.24
36.7
18
41/0.16
1.18
0.80
0.26
3.48
23.2
16
26/0.254
1.49
0.80
0.35
3.79
14.6

UL1618 Reinforced Hook-up Wire

Tinned or bare, stranded or solid copper conductor, PVC insulation

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1 

c1 AWM I A 80℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:80℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.41
0.40
1.29
381
28
7/0.127
0.38
0.41
0.40
2.00
239
26
7/0.16
0.48
0.49
0.50
2.46
150
24
11/0.16
0.61
0.46
0.50
2.53
94.2
22
17/0.16
0.76
0.48
0.48
2.68
59.4
20
26/0.16
0.94
0.41
0.42
2.60
36.7
18
41/0.16
1.18
0.41
0.38
2.76
23.2
16
26/0.254
1.49
0.41
0.40
3.12
14.6

 

UL1672 Reinforced Hook-up Wire

Tinned or bare, stranded or solid copper conductor, PVC insulation

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1 

c1 AWM I A 80℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.41
0.40
1.29
381
28
7/0.127
0.38
0.41
0.40
2.00
239
26
7/0.16
0.48
0.49
0.50
2.46
150
24
11/0.16
0.61
0.46
0.50
2.53
94.2
22
17/0.16
0.76
0.48
0.48
2.68
59.4
20
26/0.16
0.94
0.41
0.42
2.60
36.7
18
41/0.16
1.18
0.41
0.38
2.76
23.2
16
26/0.254
1.49
0.41
0.40
3.12
14.6

 

UL10800 Reinforced Halogen Free Hook-up Wire

Tinned or bare, stranded or solid copper conductor, FRPE insulation

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 80℃ 300V VW-1 

c1 AWM I A 80℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:80℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.30
0.42
1.74
381
28
7/0.127
0.38
0.30
0.42
1.82
239
26
7/0.16
0.48
0.30
0.42
1.92
150
24
11/0.16
0.61
0.30
0.42
2.05
94.2
22
17/0.16
0.76
0.30
0.42
2.20
59.4
20
26/0.16
0.94
0.30
0.42
2.38
36.7
18
41/0.16
1.18
0.30
0.42
2.62
23.2
16
26/0.254
1.49
0.30
0.42
2.93
14.6

 

UL10938 Reinforced Halogen Free Hook-up Wire

Tinned or bare, stranded or solid copper conductor, XLPE insulation

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 105℃ 600V VW-1 

c1 AWM I A 105℃ 600V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.80
0.35
2.60
381
28
7/0.127
0.38
0.80
0.35
2.68
239
26
7/0.16
0.48
0.80
0.35
2.78
150
24
11/0.16
0.61
0.80
0.35
2.91
94.2
22
17/0.16
0.76
0.80
0.35
3.06
59.4
20
26/0.16
0.94
0.80
0.35
3.24
36.7
18
41/0.16
1.18
0.80
0.35
3.48
23.2
16
26/0.254
1.49
0.80
0.35
3.79
14.6

 

UL11045 Reinforced Halogen Free Hook-up Wire

Tinned or bare, stranded or solid copper conductor, PE insulation, mPPE jacket

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 105℃ 300V VW-1 

c1 AWM I A 105℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.26
0.30
1.40
381
28
7/0.127
0.38
0.26
0.30
1.50
239
26
7/0.16
0.48
0.26
0.30
1.60
150
24
11/0.16
0.61
0.26
0.30
1.70
94.2
22
17/0.16
0.76
0.26
0.30
1.90
59.4
20
26/0.16
0.94
0.26
0.30
2.15
36.7
18
41/0.16
1.18
0.26
0.30
2.40
23.2
16
26/0.254
1.49
0.26
0.30
2.75
14.6

 

UL11047 Reinforced Halogen Free Hook-up Wire

Tinned or bare, stranded or solid copper conductor, PE insulation, mPPE jacket

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 105℃ 600V VW-1 

c1 AWM I A 105℃ 600V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:600V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.26
0.30
1.40
381
28
7/0.127
0.38
0.26
0.30
1.50
239
26
7/0.16
0.48
0.26
0.30
1.60
150
24
11/0.16
0.61
0.26
0.30
1.70
94.2
22
17/0.16
0.76
0.26
0.30
1.90
59.4
20
26/0.16
0.94
0.26
0.30
2.15
36.7
18
41/0.16
1.18
0.26
0.30
2.40
23.2
16
26/0.254
1.49
0.26
0.30
2.75
14.6

 

UL3363 Halogen Free Crosslinked Wire

Tinned or bare, stranded or solid copper conductor, 32-10AWG, XLPE insulation

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 125℃ 300V VW-1 

c1 AWM I A 125℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:125℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.38
0.15
1.36
381
28
7/0.127
0.38
0.38
0.15
1.44
239
26
7/0.16
0.48
0.38
0.15
1.54
150
24
11/0.16
0.61
0.38
0.15
1.67
94.2
22
17/0.16
0.76
0.38
0.15
1.82
59.4
20
26/0.16
0.94
0.38
0.15
2.00
36.7
18
41/0.16
1.18
0.38
0.15
2.24
23.2
16
26/0.254
1.49
0.38
0.15
2.55
14.6

 

UL3688 Halogen Free Crosslinked Wire

Tinned or bare, stranded or solid copper conductor, 30-10AWG, XLPE insulation

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 105℃ 3000V VW-1 

c1 AWM I A 105℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:3000V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
30
7/0.10
0.30
0.38
0.15
1.36
381
28
7/0.127
0.38
0.38
0.15
1.44
239
26
7/0.16
0.48
0.38
0.15
1.54
150
24
11/0.16
0.61
0.38
0.15
1.67
94.2
22
17/0.16
0.76
0.38
0.15
1.82
59.4
20
26/0.16
0.94
0.38
0.15
2.00
36.7
18
41/0.16
1.18
0.38
0.15
2.24
23.2
16
26/0.254
1.49
0.38
0.15
2.55
14.6

 

UL3737 Halogen Free Crosslinked Wire

Tinned or bare, stranded or solid copper conductor, 26-9AWG, XLPE insulation

 

1

Printing:E254881 1 AWM STYLE 1618 AWG NO. 105℃ 300V VW-1 

c1 AWM I A 105℃ 300V FT1 -LF- ELETECK

 

product manual:

- Rated temperature:105℃

- Rated voltage:300V

- Reference standard:UL758,UL1581,CSA C22.2 No.210

- Passes UL VW-1 & CSA FT1 vertical flame test

by ULVW-1and CSA FT1 CSA FT1Vertical burning test

Conductor
Insulation
Maximum Resistance
at 20℃(Ω/km)
AWG
No./mm
Diamater(mm)
Primary Layer
Thickness(mm)
Secondary
Layer
Thickness(mm)
Diamater(mm)
26
7/0.16
0.48
0.51
0.23
2.00
150
24
11/0.16
0.61
0.51
0.23
2.10
94.2
22
17/0.16
0.76
0.51
0.23
2.30
59.4
20
26/0.16
0.94
0.51
0.23
2.50
36.7
18
41/0.16
1.18
0.51
0.23
2.70
23.2
16
26/0.254
1.49
0.51
0.23
3.00
14.6