Comprehensive coverage of all areas
UL AWM Wire type 185
Let you choose worry-free
PVC Hook-up Wire
UL1007 Hook-up Wire
Tinned or bare, stranded or solid copper conductor, 32-16AWG, PVC insulation
Printing
E254881 AWM STYLE 1007 NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- -F- ELETECK
product manual
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thickness(mm)
|
Thickness(mm)
|
|
30
|
7/0.10
|
0.30
|
0.41
|
1.12
|
381
|
28
|
7/0.127
|
0.38
|
0.41
|
1.20
|
239
|
26
|
7/0.16
|
0.48
|
0.41
|
1.30
|
150
|
24
|
11/0.16
|
0.61
|
0.41
|
1.43
|
94.2
|
22
|
17/0.16
|
0.76
|
0.41
|
1.58
|
59.4
|
20
|
26/0.16
|
0.94
|
0.41
|
1.76
|
36.7
|
18
|
41/0.16
|
1.18
|
0.41
|
2.00
|
23.2
|
16
|
26/0.254
|
1.49
|
0.41
|
2.32
|
14.6
|
UL1015 Hook-up Wire
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PVC insulation
Printing
E254881 AWM STYLE 1015 NO. 105℃ 600V VW-1
C AWM I A 105℃ 600V FT1 -LF- -F- ELETECK
product manual
- Rated temperature:105℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
28
|
7/0.127
|
0.38
|
0.79
|
1.95
|
239
|
26
|
7/0.16
|
0.48
|
0.82
|
2.12
|
150
|
24
|
11/0.16
|
0.61
|
0.79
|
2.19
|
94.2
|
22
|
17/0.16
|
0.76
|
0.82
|
2.40
|
59.4
|
20
|
26/0.16
|
0.94
|
0.79
|
2.52
|
36.7
|
18
|
41/0.16
|
1.18
|
0.80
|
2.76
|
23.2
|
16
|
26/0.254
|
1.49
|
0.79
|
3.08
|
14.6
|
14
|
41/0.254
|
1.87
|
0.79
|
3.46
|
8.96
|
12
|
65/0.254
|
2.36
|
0.79
|
3.94
|
5.64
|
10
|
65/0.32
|
3.00
|
0.79
|
4.56
|
3.546
|
8
|
169/0.254
|
4.20
|
1.20
|
6.60
|
2.230
|
7
|
7/29/0.254
|
4.72
|
1.15
|
7.15
|
1.768
|
6
|
7/38/0.254
|
5.40
|
1.52
|
8.90
|
1.403
|
5
|
7/30/0.32
|
6.05
|
1.52
|
9.40
|
1.113
|
4
|
19/37/0.20
|
7.00
|
1.53
|
10.2
|
0.882
|
2
|
19/35/0.254
|
8.65
|
1.53
|
12.0
|
0.550
|
UL10269 Diamater
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PVC insulation
印字
E254881 AWM STYLE 10269 NO. 105℃ 1000V VW-1
C AWM I A 105℃ 1000V FT1 -LF- ELETECK
product manual
- Rated temperature:105℃
- Rated voltage:1000V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conducto
|
Insulation
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
28
|
7/0.127
|
0.38
|
0.79
|
1.95
|
239
|
26
|
7/0.16
|
0.48
|
0.82
|
2.12
|
150
|
24
|
11/0.16
|
0.61
|
0.79
|
2.19
|
94.2
|
22
|
17/0.16
|
0.76
|
0.82
|
2.40
|
59.4
|
20
|
26/0.16
|
0.94
|
0.79
|
2.52
|
36.7
|
18
|
41/0.16
|
1.18
|
0.80
|
2.76
|
23.2
|
16
|
26/0.254
|
1.49
|
0.79
|
3.08
|
14.6
|
14
|
41/0.254
|
1.87
|
0.79
|
3.46
|
8.96
|
12
|
65/0.254
|
2.36
|
0.79
|
3.94
|
5.64
|
10
|
65/0.32
|
3.00
|
0.79
|
4.56
|
3.546
|
8
|
169/0.254
|
4.20
|
1.20
|
6.60
|
2.230
|
7
|
7/29/0.254
|
4.72
|
1.15
|
7.15
|
1.768
|
6
|
7/38/0.254
|
5.40
|
1.52
|
8.90
|
1.403
|
5
|
7/30/0.32
|
6.05
|
1.52
|
9.40
|
1.113
|
4
|
19/37/0.20
|
7.00
|
1.53
|
10.2
|
0.882
|
2
|
19/35/0.254
|
8.65
|
1.53
|
12.0
|
0.550
|
UL10272 Hook-up Wire
Tinned or bare, stranded or solid copper conductor, 32-20AWG, PVC insulation
Printing
E254881 AWM STYLE 10272 NO. 80℃ 150V VW-1
c AWM I A 80℃ 150V FT1 -LF- ELETECK
product manual
- Rated temperature:80℃
- Rated voltage:150V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.15
|
0.65
|
381
|
28
|
7/0.127
|
0.38
|
0.15
|
0.75
|
239
|
26
|
7/0.16
|
0.48
|
0.20
|
0.85
|
150
|
24
|
11/0.16
|
0.61
|
0.20
|
1.00
|
94.2
|
22
|
17/0.16
|
0.76
|
0.25
|
1.20
|
59.4
|
20
|
26/0.16
|
0.94
|
0.25
|
1.40
|
36.7
|
UL1032 Hook-up Wire
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PVC insulation
Printing
E254881 AWM STYLE 1032 NO. 90℃ 1000V VW-1
c AWM I A 90℃ 1000V FT1 -LF- -F- ELETECK
product manual
- Rated temperature:90℃
- Rated voltage:1000V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Conductor
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
28
|
7/0.127
|
0.38
|
0.79
|
1.95
|
239
|
26
|
7/0.16
|
0.48
|
0.82
|
2.12
|
150
|
24
|
11/0.16
|
0.61
|
0.79
|
2.19
|
94.2
|
22
|
17/0.16
|
0.76
|
0.82
|
2.40
|
59.4
|
20
|
26/0.16
|
0.94
|
0.79
|
2.52
|
36.7
|
18
|
41/0.16
|
1.18
|
0.80
|
2.76
|
23.2
|
16
|
26/0.254
|
1.49
|
0.79
|
3.08
|
14.6
|
14
|
41/0.254
|
1.87
|
0.79
|
3.46
|
8.96
|
12
|
65/0.254
|
2.36
|
0.79
|
3.94
|
5.64
|
10
|
65/0.32
|
3.00
|
0.79
|
4.56
|
3.546
|
8
|
169/0.254
|
4.20
|
1.20
|
6.60
|
2.230
|
7
|
7/29/0.254
|
4.72
|
1.15
|
7.15
|
1.768
|
6
|
7/38/0.254
|
5.40
|
1.52
|
8.90
|
1.403
|
5
|
7/30/0.32
|
6.05
|
1.52
|
9.40
|
1.113
|
4
|
19/37/0.20
|
7.00
|
1.53
|
10.2
|
0.882
|
2
|
19/35/0.254
|
8.65
|
1.53
|
12.0
|
0.550
|
UL1185 Single Conductor Shielded Cable
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PVC insulation, Tinned or bare copper wire spiral shield, PVC jacket
Printing
E254881 AWM STYLE 1185 NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- ELETECK
product manual
- Rated temperature:80℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
Spiral Shield
|
Jacket
|
20℃
Maximum Resistance(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
No./mm
|
Thicknes(mm)
|
Diamater(mm)
|
|
28
|
7/0.127
|
0.38
|
0.43
|
1.24
|
38/0.1
|
0.45
|
2.34
|
239
|
26
|
7/0.16
|
0.48
|
0.43
|
1.34
|
45/0.1
|
0.45
|
2.44
|
150
|
24
|
11/0.16
|
0.61
|
0.43
|
1.47
|
46/0.1
|
0.46
|
2.58
|
94.2
|
22
|
17/0.16
|
0.76
|
0.43
|
1.62
|
54/0.1
|
0.46
|
2.74
|
59.4
|
20
|
26/0.16
|
0.94
|
0.43
|
1.80
|
56/0.1
|
0.46
|
2.92
|
36.7
|
18
|
41/0.16
|
1.18
|
0.43
|
2.04
|
64/0.1
|
0.46
|
3.16
|
23.2
|
16
|
26/0.254
|
1.49
|
0.43
|
2.36
|
74/0.1
|
0.46
|
3.48
|
14.6
|
UL1533Single Conductor Shielded Cable
Tinned or bare, stranded or solid copper conductor, 30-16AWG, PVC insulation, Tinned or bare copper wire spiral shield, PVC jacket
印字
E254881 AWM STYLE 1533 NO. 80℃ 300V VW-1
c AWM I A 80℃ 300V FT1 -LF- ELETECK
product manual
- Rated temperature:80℃
- Rated voltage:voltage not specified
- Reference standardUL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
Spiral Shield
|
Jacket
|
20℃
Maximum Resistance(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
No./mm
|
Thicknes(mm)
|
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.26
|
0.82
|
25/0.1
|
0.35
|
1.72
|
381
|
28
|
7/0.127
|
0.38
|
0.26
|
0.92
|
29/0.1
|
0.35
|
1.80
|
239
|
26
|
7/0.16
|
0.48
|
0.26
|
1.00
|
30/0.1
|
0.35
|
1.90
|
150
|
24
|
11/0.16
|
0.61
|
0.26
|
1.13
|
36/0.1
|
0.35
|
2.03
|
94.2
|
22
|
17/0.16
|
0.76
|
0.26
|
1.28
|
40/0.1
|
0.35
|
2.18
|
59.4
|
20
|
26/0.16
|
0.94
|
0.26
|
1.46
|
46/0.1
|
0.35
|
2.36
|
36.7
|
18
|
41/0.16
|
1.18
|
0.26
|
1.70
|
53/0.1
|
0.35
|
2.60
|
23.2
|
16
|
26/0.254
|
1.49
|
0.26
|
2.02
|
63/0.1
|
0.35
|
2.92
|
14.6
|
UL1569 Hook-up Wire/h3>
Tinned or bare, stranded or solid copper conductor, 30-2AWG, PVC insulation
Printing
E254881 AWM STYLE 1569 NO. 105℃ 300V VW-1
c AWM I A 105℃ 300V FT1 -LF- -F- ELETECK
Printing
- Rated temperature105℃
- Rated voltage300V
- Reference standardUL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor |
Insulation
|
20℃
Maximum Resistance(Ω/km) |
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thickness(mm)
|
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.41
|
1.12
|
381
|
28
|
7/0.127
|
0.38
|
0.41
|
1.20
|
239
|
26
|
7/0.16
|
0.48
|
0.41
|
1.30
|
150
|
24
|
11/0.16
|
0.61
|
0.41
|
1.43
|
94.2
|
22
|
17/0.16
|
0.76
|
0.41
|
1.58
|
59.4
|
20
|
26/0.16
|
0.94
|
0.41
|
1.76
|
36.7
|
18
|
41/0.16
|
1.18
|
0.41
|
2.00
|
23.2
|
16
|
26/0.254
|
1.49
|
0.41
|
2.32
|
14.6
|
UL1571 Hook-up Wire
Tinned or bare, stranded or solid copper conductor, 50AWG minimum, PVC insulation
Printing
E254881 AWM STYLE 1571 NO. 80℃ 30V VW-1
c AWM I A 80℃ 30V FT1 -LF- -F- ELETECK
product manual
- Rated temperature:80℃
- Rated voltage:30V
- Reference standardUL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
Spiral Shield
|
Jacket
|
20℃
Maximum Resistance(Ω/km) |
||||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
No./mm
|
Thicknes(mm)
|
Thicknes(mm)
|
|
32
|
7/0.8
|
0.24
|
0.23
|
0.70
|
-
|
-
|
-
|
597
|
30
|
7/0.10
|
0.30
|
0.30
|
0.90
|
28/0.1
|
0.35
|
1.80
|
381
|
30
|
7/0.10
|
0.30
|
0.20
|
0.70
|
-
|
-
|
-
|
381
|
28
|
7/0.127
|
0.38
|
0.26
|
0.90
|
28/0.1
|
0.35
|
1.80
|
239
|
28
|
7/0.127
|
0.38
|
0.26
|
0.90
|
-
|
-
|
-
|
239
|
26
|
7/0.16
|
0.48
|
0.26
|
1.00
|
-
|
-
|
-
|
150
|
24
|
7/0.20
|
0.60
|
0.26
|
1.10
|
-
|
-
|
-
|
94.2
|
22
|
17/0.16
|
0.76
|
0.32
|
1.40
|
37/0.12
|
0.58
|
2.80
|
59.4
|
22
|
17/0.16
|
0.76
|
0.25
|
1.25
|
-
|
-
|
-
|
59.4
|
20
|
26/0.16
|
0.94
|
0.43
|
1.80
|
57/0.1
|
0.56
|
3.10
|
36.7
|
18
|
65/0.127
|
1.18
|
0.30
|
1.78
|
47/0.12
|
0.59
|
3.20
|
23.2
|
16
|
54/0.18
|
1.52
|
0.32
|
2.15
|
54/0.12
|
0.61
|
3.60
|
14.6
|