Welcome to Eleteck Wire & Cable official website!

Service:/+86(0)13923630026(Sally) / +86(0)13692867958(Linda) 

Comprehensive coverage of all areas

UL AWM Wire type 185

Let you choose worry-free

Your location:
Homepage
/
/
Car single core wire

Service:

+86(0)13692867958(Linda)

+86(0)13923630614(Aries)

Car single core wire

 
 
Product description

AEX Low Voltage Cable For 48V System(日标)

1

 

Conductor: Bare Copper

Insulation: XLPE

Rating Voltage: 60VDC / 25VAC

Temperature Range: 120℃

Size: 0.5~100mm2

Flame: Ref. JASO D611

Reference Standard: JASO D611

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

- Excellent mechanical strength.

Used for 48V system high temperature parts of e-Car.

 

Conductor
Insulation

Conductor Resistance

mm2 No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)

Maximum
(Ω/km at 20℃)

0.5f
20/0.18
1.0
0.50
2.0
36.7
0.5
7/0.32
1.1
0.50
2.0
32.7
0.75f
30/0.18
1.2
0.50
2.2
24.4
0.85
11/0.32
1.2
0.50
2.2
20.8
1.25f
50/0.18
1.5
0.60
2.7
14.7
1.25
16/0.32
1.5
0.60
2.7
14.3
2f
37/0.26
1.8
0.60
3.0
9.50
2
26/0.32
1.9
0.60
3.1
8.81
3
41/0.32
2.4
0.70
3.8
5.59
5
65/0.32
3.0
0.80
4.6
3.52
8
50/0.45
3.7
0.80
5.3
2.32
15f
19/9/0.32
5.3
1.10
7.5
1.37
20f
19/13/0.32
6.5
1.10
8.7
0.946
25f
19/16/0.32
7.2
1.10
9.4
0.743
30f
19/19/0.32
7.8
1.40
10.6
0.647
35f
19/23/0.32
8.8
1.40
11.6
0.527
40f
19/26/0.32
9.1
1.40
11.9
0.473
50f
19/32/0.32
10.1
1.60
13.3
0.384
60f
19/39/0.32
11.1
1.60
14.3
0.315
85f
19/56/0.32
13.1
2.00
17.1
0.220
100f
19/71/0.32
14.9
2.00
18.9
0.173

AESSX Low Voltage Cable(日标)

1

 

Conductor: Tinned Copper

Insulation: XLPE

 

Rating Voltage: 60 VDC/25 V AC

Temperature Range:-40~120 ℃

Size: 0.3f,0.5f,0.75f,1.25f,2.0f

Flame Test: Horizontal

Reference Standard: JASO D611, JASO D618

 

Performances:

- Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

- Halogen Free.

- High temperature resistance.

- Excellent mechanical strength.

Used for high temperature parts of e-car. Such as BMS,PACK,BCU and BMU.

 

Conductor
Insulation
Conductor Resistance
mm2 No./mm Diameter Thickness Diameter/mm

Maximum
(Ω/km at 20 ℃)

0.3f
19/0.16
0.8
0.3
1.4
48.8
0.5f
19/0.19
1.0
0.3
1.6
34.6
0.75f
19/0.23
1.2
0.3
1.8
23.6
1.25f
37/0.21
1.5
0.3
2.1
14.6
2.0f
39/0.26
1.8
0.4
2.6
9.5

The ̋f ̋ in the mm2 column indicates a flexible conductor with a fine wire diameter.

 

 

AV Low Voltage Cable(日标)

1

 

Conductor: Bare Copper

Insulation: PVC

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: 80℃

Size: 0.50~100mm2

Flame: Ref. JIS C 3406

Reference Standard: JIS C 3406

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

- Excellent mechanical strength.

Internal wiring in automobile where high flexibility, thermo and mechanical strength are required.

 

Conductor
Insulation
Conductor Resistance
mm² No./mm Diameter
(mm)
Thickness(mm) Diameter(mm)

Maximum
(Ω/km at 20℃)

0.5f
20/0.18
1.0
0.60
2.2
36.7
0.5
7/0.32
1.0
0.0.60
2.2
32.7
0.75f
30/0.18
1.2
0.60
2.4
24.4
0.85
11/0.32
1.2
0.60
2.4
20.8
1.0f
57/0.15
1.3
0.60
2.5
18.5
1.25f
50/0.18
1.5
0.60
2.7
14.7
1.25
16/0.32
1.5
0.60
2.7
14.3
2
26/0.32
1.9
0.60
3.1
8.81
3
41/0.32
2.4
0.70
3.8
5.59
5
65/0.32
3.0
0.80
4.6
3.52
8
50/0.45
3.7
0.90
5.5
2.32
15
84/0.45
4.8
1.10
7.0
1.38
20
41/0.80
6.0
1.10
8.2
0.887
30
70/0.80
8.0
1.40
10.8
0.520
40
85/0.80
8.6
1.40
11.4
0.428
50
108/0.80
9.8
1.60
13.0
0.337
60
127/0.80
10.4
1.60
13.6
0.287
85
169/0.80
12.0
2.0
16.0
0.215
100
217/0.80
13.0
2.0
17.6
0.168

 

 

AVS Low Voltage Cable(日标)

1

 

Conductor: Bare Copper

Insulation: PVC

Rating Voltage: 60VDC / 25VAC

Temperature Range: 80℃

Size: 0.30~8.0mm2

Flame: Ref. JASO D611

Reference Standard: JASO D611

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

- Excellent mechanical strength.

Internal wiring in automobile where high flexibility, thermo and mechanical strength are required.

 

Conductor
Insulation
Conductor Resistanc
mm²
No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)

Maximum
(Ω/km at 20℃)

0.3
7/0.26
0.8
0.50
1.8
50.2
0.3f
15/0.18
0.8
0.50
1.8
48.9
0.35f
20/0.15
0.9
0.50
1.9
52.0
0.5f
20/0.18
1.0
0.50
2.0
36.7
0.5
7/0.32
1.0
0.50
2.0
32.7
0.75f
30/0.18
1.2
0.50
2.2
24.4
0.85
16/0.26
1.2
0.50
2.2
20.8
11/0.32
1.2
0.50
2.2
22.0
1.0f
57/0.15
1.3
0.50
2.3
18.5
1.25f
50/0.18
1.5
0.50
2.5
14.7
1.25
16/0.32
1.5
0.50
2.5
14.3
2f
37/0.26
1.9
0.50
3.0
9.50
2
26/0.32
1.9
0.50
3.0
8.81
3f
58/0.26
2.3
0.60
3.5
6.06
3
41/0.32
2.4
0.60
3.6
5.59
5
65/0.32
3.0
0.70
4.4
3.52
5f
7/30/0.16
3.4
0.70
4.8
3.56
8
50/0.45
3.7
0.80
5.3
2.32
8f
7/22/0.26
3.7
0.80
5.3
2.32

 

 

AVSS Low Voltage Cable(日标)

1

 

Conductor: Bare Copper

Insulation: PVC

Rating Voltage: 60VDC / 25VAC

Temperature Range: 80℃

Size: 0.30~8.0mm2

Flame: Ref. JASO D611

Reference Standard: JASO D611

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

- Excellent mechanical strength.

Internal wiring in automobile where high flexibility, thermo and mechanical strength are required.

 

Conductor
Insulation
Conductor Resistance
mm²
No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)
Maximum
(Ω/km at 20℃)
0.22
7/0.20
0.6
0.30
1.2
84.8
7/圆形压缩
0.55
0.35
1.25
84.8
0.3
7/0.26
0.8
0.30
1.4
50.2
7/圆形压缩
0.7
0.35
1.4
50.2
0.3f
19/0.16
0.8
0.30
1.4
48.8
0.35f
20/0.15
0.9
0.30
1.5
52.0
0.5f
19/0.19
1.0
0.30
1.6
34.6
0.5
7/0.32
1.0
0.30
1.6
32.7
7/圆形压缩
0.9
0.35
1.6
32.7
0.75f
30/0.18
1.2
0.30
1.8
23.6
0.85
19/0.24
1.2
0.30
1.8
21.7
7/0.40
1.2
0.30
1.8
20.8
7/圆形压缩
1.1
0.35
1.8
20.8
11/圆形压缩
1.1
0.35
1.8
20.8
1.0f
57/0.15
1.3
0.30
1.9
18.5
1.25
19/0.29
1.5
0.30
2.1
14.9
16/圆形压缩
1.4
0.35
2.1
14.9
1.25f
37/0.21
1.5
0.30

2.1

14.6
2f
37/0.26
1.8
0.40
2.6
9.50
2
19/0.37
1.9
0.40
2.7
9.00



QVR-105 Low Voltage Cable(国标)

1

 

Conductor: Bare Copper

Insulation: PVC

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: 105℃

Size: 0.30~120mm2

Flame: Ref. JB/T 8139

Reference Standard: JB/T 8139

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

- Excellent mechanical strength.

Internal wiring in automobile where high flexibility, thermo and mechanical strength are required.

 

Conductor
Insulation
Conductor Resistance
mm²
No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)
Maximum
(Ω/km at 20℃)
0.2
12/0.15
0.59
0.3
1.25
92.3
0.3
16/0.15
0.69
0.3
1.35
69.2
0.4
23/0.15
0.83
0.3
1.50
48.2
0.5
16/0.20
0.92
0.6
2.30
39.0
0.75
24/0.20
1.13
0.6
2.45
26.0
1.0
32/0.20
1.30
0.6
2.65
19.5
1.5
30/0.25
1.57
0.6
3.00
13.3
2.5
49/0.25
2.02
0.7
3.60
7.98
4
56/0.30
2.59
0.8
4.30
4.95
6
84/0.30
3.17
0.8
4.90
3.30
10
84/0.40
4.23
1.0
6.50
1.91
16
126/0.40
5.18
1.0
7.80
1.21
25
196/0.40
6.46
1.3
9.80
0.780
35
276/0.40
7.67
1.3
11.0
0.554
50
396/0.40
9.19
1.5
13.0
0.386
70
360/0.50
10.95
1.5
14.8
0.272
95
475/0.50
12.58
1.6
17.0
0.206
120
608/0.50
14.23
1.6
18.7
0.161

 

 

FLRY-A LOW Voltage Cable(德标)

1

 

Conductor: Bare Copper

Insulation: PVC

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: -40~105℃

Size: 0.22~2.5mm2

Flame: Ref.DIN 72551

Reference Standard: DIN 72551

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

Used for EV, Motor, Fan Motor, Sensor etc.

 

Conductor
Insulation
Conductor Resistance
mm²
No./mm
Diameter
Max. (mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
0.22
7/0.21
0.70
0.20
1.2
84.8
0.35
7/0.26
0.80
0.20
1.3
52.0
0.50
19/0.19
1.00
0.22
1.6
37.1
0.75
19/0.23
1.20
0.24
1.9
24.7
1.0
19/0.26
1.35
0.24
2.1
18.5
1.5
19/0.32
1.70
0.24
2.4
12.7
2.0
19/0.37
2.0
0.24
2.6
9.42
2.5
19/0.41
2.2
0.28
3.0
7.6

 

FLRY-B LOW Voltage Cable(德标)

1

 

Conductor: Bare Copper

Insulation: PVC

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: -40~105℃

Size: 0.35~6.0mm2

Flame: Ref.DIN 72551

Reference Standard: DIN 72551

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

Used for EV, Motor, Fan Motor, Sensor etc.

 

Conductor
Insulation
Conductor Resistance
mm²
No./mm
Diameter
Max. (mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
0.35
12/0.21
0.90
0.20
1.4
52.0
0.5
16/0.21
1.00
0.22
1.6
37.1
0.75
24/0.21
1.20
0.24
1.9
24.7
1.0
32/0.21
1.35
0.24
2.1
18.5
1.5
30/0.26
1.70
0.24
2.4
12.7
2.0
28/0.31
1.90
0.24
2.6
9.42
2.5
50/0.26
2.20
0.28
3.0
7.6
3.0
45/0.31
2.24
0.28
3.2
6.21
4.0
56/0.31
2.75
0.32
3.7
4.7
6.0
84/0.31
3.30
0.32
4.3
3.1

 

GXL Low Voltage Cable(美标)

1

 

Conductor: Bare Copper

Insulation: XLPE

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: 125℃

Size: 20~8AWG

Flame: Ref.SAE J1128

Reference Standard: SAE J1128

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

- Halogen Free.

Used for Internal wiring in automobile.

 

Conductor
Insulation
Conductor Resistance
AWG/mm²
No./mm
Diameter
(mm)
Thickness
Nominal (mm)
Diameter
Max.(mm)
Maximum
(Ω/km at 20 ℃)
20/0.5
7/0.31
0.93
0.58
2.40
34.6
18/0.8
19/0.23
1.15
0.58
2.50
21.8
16/1.0
19/0.28
1.40
0.58
2.90
13.7
14/2.0
19/0.36
1.80
0.58
3.20
8.62
12/3.0
19/0.45
2.25
0.66
3.80
5.43
10/5.0
19/0.57
2.85
0.79
4.70
3.41
8/8.0
19/0.71
3.55
0.94
6.00
2.14

 

SXL Low Voltage Cable(美标)

1

 

Conductor: Bare Copper

Insulation: XLPE

 

Rating Voltage: 60VDC / 25VAC

Temperature Range: 105℃

Size: 20~8AWG

Flame: Ref.SAE J1128

Reference Standard: SAE J1128

 

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

Used for Internal wiring in automobile

 

Conductor
Insulation
Conductor Resistance
AWG/mm2
No./mm
Diameter
(mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
20/0.5
7/0.31
0.93
0.40
2.80
34.6
18/0.8
19/0.23
1.15
0.40
3.00
21.8
16/1.0
19/0.28
1.40
0.40
3.40
13.7
14/2.0
19/0.36
1.80
0.40
3.90
8.62
12/3.0
19/0.45
2.25
0.46
4.60
5.43
10/5.0
19/0.57
2.85
0.50
5.30
3.41
8/8.0
19/0.71
3.55
0.55
6.20
2.14

 

TXL Low Voltage Cable(美标)

1

Conductor: Bare Copper

Insulation: XLPE

Rating Voltage: 60VDC / 25VAC

Temperature Range: 125℃

Size: 24~8AWG

Flame: Ref.SAE J1128

Reference Standard: SAE J1128

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

- Halogen Free.

Used for Internal wiring in automobile

Conductor
Insulation
Conductor Resistance
AWG/mm2
No./mm
Diameter
(mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
24/0.22
7/0.20
0.60
0.40
1.50
87.6
22/0.35
7/0.254
0.76
0.40
1.70
55.4
20/0.5
7/0.31
0.93
0.40
1.90
34.6
18/0.8
19/0.23
1.15
0.40
2.20
21.8
16/1.0
19/0.28
1.40
0.40
2.40
13.7
14/2.0
19/0.36
1.80
0.40
2.70
8.62
12/3.0
19/0.45
2.25
0.46
3.30
5.43
10/5.0
19/0.57
2.85
0.50
4.00
3.41
8/8.0
19/0.71
3.55
0.55
4.90
2.14

 

GPT Low Voltage Cable(美标)

1

Conductor: Bare Copper

Insulation: PVC

Rating Voltage: 60VDC / 25VAC

Temperature Range: 105℃

Size: 20~8AWG

Flame: Ref.SAE J1128

Reference Standard: SAE J1128

Performances:

u Easy installation.

u Easy stripping and cutting.

u Resistance to acids, alkalis, oil.

u RoHS and REACH compliant.

Used for Internal wiring in automobile

Conductor
Insulation
Conductor Resistance
AWG/mm2
No./mm
Diameter
(mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
20/0.5
7/0.31
0.93
0.58
2.40
34.6
18/0.8
19/0.23
1.15
0.58
2.50
21.8
16/1.0
19/0.28
1.40
0.58
2.90
13.7
14/2.0
19/0.36
1.80
0.58
3.20
8.62
12/3.0
19/0.45
2.25
0.66
3.80
5.43
10/5.0
19/0.57
2.85
0.79
4.70
3.41
8/8.0
19/0.71
3.55
0.94
6.00
2.14

 

 

TWP Low Voltage Cable(美标)

 

Conductor: Bare Copper

Insulation: PVC

Rating Voltage: 60VDC / 25VAC

Temperature Range: 125℃

Size: 24~8AWG

Flame: Ref.SAE J1128

Reference Standard: SAE J1128

Performances:

- Easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

Used for Internal wiring in automobile

Conductor
Insulation
Conductor Resistance
AWG/mm2
No./mm
Diameter
(mm)
Thickness
Nominal (mm)
Diameter
Max. (mm)
Maximum
(Ω/km at 20 ℃)
24/0.22
7/0.20
0.60
0.40
1.50
87.6
22/0.35
7/0.254
0.76
0.40
1.70
55.4
20/0.5
7/0.31
0.93
0.40
1.90
34.6
18/0.8
19/0.23
1.15
0.40
2.20
21.8
16/1.0
19/0.28
1.40
0.40
2.40
13.7
14/2.0
19/0.36
1.80
0.40
2.70
8.62
12/3.0
19/0.45
2.25
0.46
3.30
5.43
10/5.0
19/0.57
2.85
0.50
4.00
3.41
8/8.0
19/0.71
3.55
0.55
4.90
2.14