Welcome to Eleteck Wire & Cable official website!

Service:/+86(0)13923630026(Sally) / +86(0)13692867958(Linda) 

Comprehensive coverage of all areas

UL AWM Wire type 185

Let you choose worry-free

Your location:
Homepage
/
/
EV Charging Cable for AC China

Service:

+86(0)13692867958(Linda)

+86(0)13923630614(Aries)

EV Charging Cable for AC China

 
 
Product description

EV Charging Cable for AC China

Type: EV-RSS, EV-RS90U, EV-RSSPS, EV-RS90S90PU

1
1

 

 

 

 

(L,N,PE)*3C+(CP)*1C    (L,N,PE)*3C+(CP,CC)*2C 

Conductor: Bare Copper

Insulation: TPE

Shielding: Tinned Copper, Over 80%,Optional

Jacket: TPE or TPU

 

Rating Voltage: 450/750 V AC

Temperature Range: -40~+90 ℃ (TPE: -25~+70 ℃, TPU: -40~+90 ℃)

Size: 1.0~70 mm2

Flame Test: Ref. GB/T 33594-2017

Reference Standard: GB/T 33594-2017

 

Performances:

Extra Flexible and easy installation.

Easy stripping and cutting.

Resistance to acids, alkalis, oil.

RoHS and REACH compliant.

Halogen Free.

For e-Car AC Charging

 

(L,N,PE)*3C+(CP)*1C

Conductor

  Insulation

 Braiding

 Jacket

  Resist.
(20℃) Ω/Km

Cords

mm2

No./mm

Diameter

Thickness

Diameter/mm

Shield

Coverage

Thickness

Diameter

Num. (mm) (mm) (mm) (mm) (mm)
3+1
1.0*3C
32/0.20
1.3
0.8
2.9
24/6/0.15
1.8
13.0
19.5
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
1.5*3C
48/0.20
1.6
0.8
3.2
24/6/0.15
1.9
13.0
13.2
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
2.5*3C
80/0.20
2
0.8
3.6
24/7/0.15
2.0
14.0
7.98
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
4.0*3C
126/0.20
2.6
1
4.6
24/7/0.15
2.2
17.0
4.95
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
6.0*3C
189/0.20
3.2
1
5.2
16/8/0.20
2.3
18.0
3.30
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
10.0*3C
322/0.20
4.3
1
6.3
16/8/0.20
2.5
20.0
1.91
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
16.0*3C
511/0.20
5.2
1.2
7.2
24/6/0.20
2.7
22.0
1.21
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
25.0*3C
798/0.20
6.5
1.2
8.9
24/6/0.20
3.1
26.0
0.780
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
35.0*3C
1121/0.20
8.2
1.2
10.6
24/6/0.20
3.5
30.0
0.554
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
50.0*3C
1596/0.20
9.6
1.4
12.4
24/6/0.20
3.9
 
35.0
 
0.386
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+1
70.0*3C
2223/0.20
11.6
1.4
14.4
-
4.4
40.0
0.272
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2

 

(L,N,PE)*3C+(CP,CC)*2C

 Conductor

  Insulation

 Braiding

Jacket

  Resist. (20℃)

Ω/Km

Cords
mm2
No./mm
Diameter
Thickness
Diameter

Shield

Coverage

Thickness
Diameter

Num.

(mm) (mm) (mm) (mm) (mm)
3+2
1.0*3C
32/0.20
1.3
0.8
2.9
24/6/0.15
1.1
11.0
19.5
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
1.5*3C
48/0.20
1.6
0.8
3.2
24/6/0.15
1.1
12.0
13.2
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
2.5*3C
80/0.20
2
0.8
3.6
24/7/0.15
1.2
13.0
7.98
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
4.0*3C
126/0.20
2.6
1
4.6
24/7/0.15
1.3
15.0
4.95
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
6.0*3C
189/0.20
3.2
1
5.2
16/8/0.20
1.4
16.0
3.30
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
10.0*3C
322/0.20
4.3
1
6.3
16/8/0.20
1.5
18.0
1.91
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
16.0*3C
511/0.20
5.2
1.2
7.2
24/6/0.20
1.6
20.0
1.21
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
25.0*3C
798/0.20
6.5
1.2
8.9
24/6/0.20
1.8
24.0
0.780
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
35.0*3C
1121/0.20
8.2
1.2
10.6
24/6/0.20
2.1
28.0
0.554
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
50.0*3C
1596/0.20
9.6
1.4
12.4
24/6/0.20
2.3
32.0
0.386
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2
3+2
70.0*3C
2223/0.20
11.6
1.4
14.4
-
2.6
36.0
0.272
0.75*1C
41/0.16TC
1.18
0.5
2.2
23.2

L: Live; N: Neutral; PE: Protection Earth; CP: Control Protection; CC: Charging Confirmation

 

  EV Charging Cable for DC China

Type: EVDC-RSS, EVDC-RSSPS

Conductor: Bare Copper

Insulation: TPE

Shielding: Tinned Copper, Over 80%, Optional

Jacket: TPE

 

Rating Voltage: 1000 V DC

Temperature Range: -25~+70 ℃

Size: 10~95 mm2

Flame Test: Ref. GB/T 33594-2017

Reference Standard: GB/T 33594-2017

 

Performances:

- Extra Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and REACH compliant.

- Halogen Free.

For e-Car DC Charging.

 

(DC+,DC-)*2C+PE*1C+(A+,A-)*2C+(S+,S-,CC1,CC2)*4C

Conductor

Insulation
Braiding
Jacket
Resist.
(20℃) Ω/Km
Cords
mm
No./mm
Diameter
(mm)
Thickness
Diameter/mm
Shield
Thickness
Num. (mm) (mm) (mm) (mm) (mm)
2+1+2+4
 
10.0*2C
322/0.20
4.3
1.0
6.3
24/6/0.20
2.4
19.0
1.91
6.0*1C
189/0.20
3.2
1.0
5.2
3.30
4.0*2C
126/0.20
2.6
1.0
4.6
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
16.0*2C
511/0.20
5.2
1.0
7.2
24/6/0.20
2.7
22.0
1.21
10.0*1C
322/0.20
4.3
1.0
6.3
1.91
4.0*2C
126/0.20
2.6
1.0
4.6
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
25.0*2C
798/0.20
6.5
1.2
8.9
24/5/0.25
3.2
27.0
0.780
16.0*1C
511/0.20
5.2
1.0
7.2
1.21
4.0*2C
126/0.20
2.6
1.0
4.6
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
35.0*2C
1121/0.20
8.2
1.2
10.6
24/5/0.25
3.5
30.0
0.554
25.0*1C
798/0.20
6.5
1.2
8.9
0.780
4.0*2C
126/0.20
2.6
1.0
4.6
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
50.0*2C
1596/0.20
9.6
1.4
12.4
-
3.9
35.0
0.386
35.0*1C
1121/0.20
8.2
1.2
10.6
0.554
4.0*2C
126/0.20
2.6
1.0
4.60
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
70.0*2C
2223/0.20
11.6
1.4
14.4
-
4.4
40.0
0.272
50.0*2C
1596/0.20
9.6
1.4
12.4
0.386
4.0*2C
126/0.20
2.6
1.0
4.60
0.495
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2
2+1+2+4
 
95.0*2C
3034/0.20
13.2
1.5
16.2
-
4.8
45.0
0.206
70.0*2C
2223/0.20
11.6
1.4
14.4
0.272
4.0*2C
126/0.20
2.6
1.0
4.60
4.95
0.75*4C
41/0.16TC
1.18
0.5
2.2
23.2

 

  EV Charging Cable

Type: EVE 105℃ 1000V, EVE 90℃ 600V, EVJE 105℃ 300V, EVJE 90℃ 300V

UL EV Charging Cable

Type: EVE

1

(DC+,DC-,PE)*3C+(CP)*1C

 

Conductor: Bare Copper

Insulation: TPE

Shielding: Tinned Copper, Over 80%,Optional

Jacket: TPE

Rating Voltage: 600V

Temperature Range: -40~+90 ℃

Flame Test: Ref. UL62

Reference Standard: UL62

Performances:

Extra Flexible and easy installation.

Easy stripping and cutting.

Resistance to acids, alkalis, oil.

RoHS and REACH compliant.

Halogen Free.

For e-Car Charging

 

(DC+,DC-,PE)*3C+(CP)*1C

 Conductor

  Insulation

 Braiding

Jacket

  Resist. (20℃)

Ω/Km

Cords
AWG
No./mm
Diameter
Thickness
Diameter

Shield

Coverage

Thickness
Diameter

Num.

(mm) (mm) (mm) (mm) (mm)
3+1

10awg*3C

168/0.20
3.20
1.14
5.6
-
2.03
16.5
3.51

22awg*1C

11/0.20
0.76
0.76
2.4
56.2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
         
 
 
 
 
       
 
 
 
           
 
 
 
       
 
 
 
           
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
       
 
 
 
 
 
       
 
 
 
       
 
 
 
 
 
       
 


UL EV Charging Cable

 

Type: EVJE

1

(DC+,DC-,PE)*3C+(S+,S-,CP)*3C

 

Conductor: Bare Copper

Insulation: TPE

Shielding: Tinned Copper, Over 80%,Optional

Jacket: TPE

 

Rating Voltage: 300V

Temperature Range: -40~+90 ℃

Flame Test: Ref. UL62

Reference Standard: UL62

Performances:

Extra Flexible and easy installation.

Easy stripping and cutting.

Resistance to acids, alkalis, oil.

RoHS and REACH compliant.

Halogen Free.

For e-Car Charging

 

(DC+,DC-,PE)*3C+(S+,S-,CP)*1C

 Conductor

  Insulation

 Braiding

Jacket

  Resist. (20℃)

Ω/Km

Cords
AWG
No./mm
Diameter
Thickness
Diameter

Shield

Coverage

Thickness
Diameter

Num.

(mm) (mm) (mm) (mm) (mm)
3+3

14awg*3C

66/0.20
1.87
1.87
3.60
-
0.76
12.2
8.88

20awg*3C

17/0.20
0.96
0.95
2.6
35.7
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
         
 
 
 
 
       
 
 
 
           
 
 
 
       
 
 
 
           
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
         
 
 
 
 
       
 
 
 
       
 
 
 
 
 
       
 
 
 
       
 
 
 
 
 
       
 

 

1

1

1

1

1

1