Welcome to Eleteck Wire & Cable official website!

Service:/+86(0)13923630026(Sally) / +86(0)13692867958(Linda) 

Comprehensive coverage of all areas

UL AWM Wire type 185

Let you choose worry-free

Your location:
Homepage
/
/
EV High Voltage Cable On-Board

Service:

+86(0)13692867958(Linda)

+86(0)13923630614(Aries)

EV High Voltage Cable On-Board

 
 
Product description

EV High Voltage Cable On-Board

TPE or XLPE or Silicone Rubber Non-shielding Cable (QC/T 1037)

1

 

Conductor: Bare Copper

Insulation: TPE or XLPE or Silicone Rubber

 

Description:

Rating Voltage: 1500 VDC / 1000 VAC

Temperature Range:-65~200℃ (TPE:-40~105℃, XLPE:-40~125℃ or 150℃, SR.: -65~200℃)

Size:2.5~150mm2

Flame:Ref. QC/T 1037-2016

Reference Standard:QC/T 1037-2016

 

Performances:

- Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

 

Used for EV Motor, PDU, BMS, MCU, Energy storage systems, etc

 

Conductor
Insulation

Conductor Resistance

mm2
No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)

Maximum
(Ω/km at 20℃)

2.5
80/0.20
2.00
0.80
3.70
7.600
4
126/0.20
2.60
0.80
4.30
4.710
6
189/0.20
3.20
0.80
4.90
3.140
10
322/0.20
4.30
1.00
6.40
1.820
16
511/0.20
5.20
1.10
7.90
1.160
25
798/0.20
6.50
1.30
9.60
0.743
35
1121/0.20
8.20
1.30
11.10
0.527
50
1596/0.20
9.60
1.50
12.90
0.368
70
2223/0.20
11.60
1.50
15.00
0.259
95
3034/0.20
13.20
1.50
16.50
0.196
120
3811/0.20
14.60
1.60
18.40
0.153
135
4292/0.20
15.40
1.70
19.20
0.138
150
4810/0.20
16.20
1.80
20.40
0.129

 

EV High Voltage Cable On-Board

TPE or XLPE or Silicone Rubber with Shielding Cable (QC/T 1037)

1

 

Conductor: Bare Copper

Insulation: TPE or XLPE or Silicone Rubber

Shielding: Tinned Copper (≥85%)

Jacket: TPE or XLPE or Silicone Rubber

 

Description:

Rating Voltage:1500 VDC/1000 VAC

Temperature Range: -65~200℃ (TPE:-40~105℃, XLPE:-40~125℃ or 150℃, SR.: -65~200℃)

Size:2.50~150mm2

Flame:Ref. QC/T 1037-2016

Reference Standard:QC/T 1037-2016

 

Performances:

- Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis oil.

- RoHS and Reach compliant.

- Halogen Free.

- Excellent EMI, EMC noise reduction.

 

Used for EV Motor, PDU, BMS, MCU, Energy storage systems, Etc.

 

Conductor
Insulation
Braiding
Jacket
Conductor Resistance
 
mm²
No./mm
Diameter
(mm)
Thickness
(mm)
Diameter
(mm)
Shield
Coverage
Thickness
(mm)
Maximum
(Ω/km at 20℃)
2.5
80/0.20
2.00
0.80
3.70
16/6/0.16
0.60
5.50
7.600
4
126/0.20
2.60
0.80
4.30
16/7/0.16
0.60
6.10
4.710
6
189/0.20
3.20
0.80
4.90
16/7/0.16
0.70
6.90
3.140
10
322/0.20
4.30
1.00
6.40
16/9/0.16
0.80
8.90
1.820
16
511/0.20
5.20
1.10
7.90
16/10/0.16
1.30
11.40
1.160
25
798/0.20
6.50
1.30
9.60
16/11/0.16
1.50
13.70
0.743
35
1121/0.20
8.20
1.30
11.10
24/8/0.16
1.50
15.00
0.527
50
1596/0.20
9.60
1.50
12.90
24/8/0.16
1.70
17.20
0.368
70
2223/0.20
11.60
1.50
15.00
24/9/0.16
1.70
19.20
0.259
95
3034/0.20
13.20
1.50
16.50
24/9/0.16
1.70
20.70
0.196
120
3811/0.20
14.60
1.60
18.40
24/9/0.16
1.70
22.80
0.153
135
4292/0.20
15.40
1.70
19.20
24/9/0.16
1.70
23.50
0.138
150
4810/0.20
16.20
1.80
20.40
24/9/0.16
2.00
25.50
0.129

 

EV High Voltage Cable On-Board

Silicone Rubber Non-shielding Cable (LV-216-1)

1

 

Conductor: Bare Copper

Insulation: Silicone Rubber

 

Description:

Rating Voltage:1500 VDC /1000 VAC

Temperature Range:-65~200℃

Size:2.5~150mm2

Flame:Ref. LV-216-1

Reference Standard: LV-216-1

 

Performances:

- Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis, oil.

- RoHS and Reach compliant.

 

Used for EV Motor, PDU, BMS, MCU, Energy storage systems, etc

 

Conductor
Insulation
Conductor Resistance
mm²
No./mm
Diameter
(mm)
Min. Thickness
(mm)
Diameter
(mm)
Maximum
(Ω/km at 20℃)
0.35
20/0.15
0.80
0.24
2.1(-0.3)
52.0
0.50
29/0.15
0.92
0.24
2.3(-0.3)
37.1
0.75
43/0.15
1.13
0.24
2.5(-0.3)
24.7
1.0
57/0.15
1.30
0.24
2.7(-0.3)
18.5
1.5
85/0.15
1.59
0.24
3.0(-0.3)
12.7
2.0
114/0.15
1.84
0.28
3.3(-0.3)
9.42
2.5
80/0.20
2.00
0.28
3.6(-0.3)
7.60
4
126/0.20
2.60
0.32
4.4(-0.4)
4.71
6
189/0.20
3.20
0.32
5.0(-0.4)
3.14
10
322/0.20
4.30
0.48
6.5(-0.6)
1.82
16
511/0.20
5.20
0.52
8.3(-0.6)
1.16
25
798/0.20
6.50
0.64
10.0(-0.6)
0.743
35
1121/0.20
8.20
0.64
11.0(-0.7)
0.527
50
1596/0.20
9.60
0.71
13.2(-0.8)
0.368
70
2223/0.20
11.60
1.20
15.1(-0.8)
0.259
95
3034/0.20
13.20
1.20
17.4(-1.0)
0.196
120
3811/0.20
14.60
1.28
19.5(-1.0)
0.153

 

EV High Voltage Cable On-Board

Silicone Rubber with Shielding Cable (LV-216-2)

1

 

Conductor: Bare Copper

Insulation: Silicone Rubber

Shielding: Tinned Copper (≥85%)

Jacket: Silicone Rubber

 

Description:

Rating Voltage:1500VDC/1000VAC

Temperature Range: -65~200℃

Size:2.50~150mm2

Flame:Ref. LV-216-2

Reference Standard: LV-216-2

 

Performances:

- Flexible and easy installation.

- Easy stripping and cutting.

- Resistance to acids, alkalis oil.

- RoHS and Reach compliant.

- Halogen Free.

- Excellent EMI, EMC noise reduction.

 

Used for EV Motor, PDU, BMS, MCU, Energy storage systems, Etc.

 

Conductor
Insulation
Braiding
Jacket
Conductor Resistance
 
mm²
No./mm
Diameter
(mm)
Min Thickness
(mm)
Diameter
(mm)
Shield
Coverage
Min Thickness
(mm)
Maximum
(Ω/km at 20℃)
1.5
85/0.15
1.59
0.24
2.4(-0.2)
16/5/0.12
0.38
4.0(-0.5)
12.7
2.0
114/0.15
1.84
0.24
2.8(-0.3)
16/5/0.12
0.38
4.5(-0.5)
9.40
2.5
80/0.20
2.00
0.28
3.0(-0.3)
16/6/0.16
0.38
4.7(-0.5)
7.60
4
126/0.20
2.60
0.32
3.7(-0.3)
16/7/0.16
0.38
5.8(-0.5)
4.71
6
189/0.20
3.20
0.32
4.3(-0.3)
16/7/0.16
0.46
6.5(-0.5)
3.14
10
322/0.20
4.30
0.48
6.0(-0.6)
16/9/0.16
0.70
8.8(-0.6)
1.82
16
511/0.20
5.20
0.52
7.2(-0.6)
16/10/0.16
0.70
10.2(-0.6)
1.16
25
798/0.20
6.50
0.64
8.8(-0.6)
16/11/0.16
0.75
12.2(-0.6)
0.743
35
1121/0.20
8.20
0.64
10.5(-0.7)
24/8/0.16
0.80
14.4(-0.7)
0.527
50
1596/0.20
9.60
0.71
12.2(-0.7)
24/8/0.16
0.80
15.8(-0.6)
0.368
70
2223/0.20
11.60
1.20
15.5(-1.5)
24/9/0.16
1.16
20.0(-0.8)
0.259
95
3034/0.20
13.20
1.20
18.0(-1.8)
24/9/0.16
1.16
22.5(-1.0)
0.196
120
3811/0.20
14.60
1.28
19.7(-1.8)
24/9/0.16
1.16
23.5(-1.0)
0.153