Comprehensive coverage of all areas
UL AWM Wire type 185
Let you choose worry-free
PFA Insulated Wire
UL1726 PFA Insulated Wire
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PFA insulation
Printing
E254881 AWM STYLE 1726 AWG NO. 250℃ 300V VW-1
c AWM I A 250℃ 300V FT1 -LF- ELETECK
Product manual
- Rated temperature:250℃
- Rated voltage:300V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance
at(Ω/km)
|
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.33
|
0.96
|
381
|
28
|
7/0.12
|
0.36
|
0.33
|
1.02
|
239
|
26
|
7/0.16
|
0.48
|
0.33
|
1.14
|
150
|
24
|
19/0.12
|
0.60
|
0.33
|
1.26
|
94.2
|
22
|
7/0.25
|
0.75
|
0.33
|
1.41
|
59.4
|
22
|
19/0.15
|
0.75
|
0.33
|
1.41
|
59.4
|
20
|
7/0.31
|
0.93
|
0.33
|
1.59
|
36.7
|
20
|
19/0.19
|
0.93
|
0.33
|
1.59
|
36.7
|
UL10064 PFA Insulated Wire
Tinned or bare, stranded or solid copper conductor, 40AWG minimum, PFA insulation
Printing
E254881 AWM STYLE 10064 AWG NO. 105℃ 30V VW-1
c AWM I A 105℃ 30V FT1 -LF- ELETECK(线径小于1.0MM不印字)
Product manual
- Rated temperature:105℃
- Rated voltage:30V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance
at(Ω/km)
|
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
36
|
7/0.05
|
0.15
|
0.06
|
0.27
|
1552
|
34
|
7/0.06
|
0.18
|
0.06
|
0.30
|
978
|
34
|
7/0.06
|
0.18
|
0.07
|
0.32
|
978
|
32
|
7/0.08
|
0.24
|
0.05
|
0.34
|
601
|
32
|
7/0.08
|
0.24
|
0.07
|
0.38
|
601
|
30
|
7/0.10
|
0.30
|
0.10
|
0.50
|
381
|
28
|
7/0.12
|
0.36
|
0.10
|
0.56
|
239
|
26
|
7/0.16
|
0.48
|
0.10
|
0.70
|
150
|
UL10362 PFA Insulated Wire
Tinned or bare, stranded or solid copper conductor, 30-4/0AWG, PFA insulation
Printing
E254881 AWM STYLE 10362 AWG NO. 250℃ 600V VW-1
c AWM I A 250℃ 600V FT1 -LF- ELETECK
Product manual
- Rated temperature:250℃
- Rated voltage:600V
- Reference standard:UL758,UL1581,CSA C22.2 No.210
- Passes UL VW-1 & CSA FT1 vertical flame test
Conductor
|
Insulation
|
20℃
Maximum Resistance
at(Ω/km)
|
|||
AWG
|
No./mm
|
Diamater(mm)
|
Thicknes(mm)
|
Diamater(mm)
|
|
30
|
7/0.10
|
0.30
|
0.26
|
0.82
|
381
|
28
|
7/0.12
|
0.36
|
0.26
|
0.88
|
239
|
26
|
7/0.16
|
0.48
|
0.26
|
1.00
|
150
|
24
|
19/0.12
|
0.60
|
0.26
|
1.12
|
94.2
|
22
|
7/0.25
|
0.75
|
0.26
|
1.27
|
59.4
|
22
|
19/0.15
|
0.75
|
0.26
|
1.27
|
59.4
|
20
|
7/0.31
|
0.93
|
0.26
|
1.45
|
36.7
|
20
|
19/0.19
|
0.93
|
0.26
|
1.45
|
36.7
|